(K)PQg - Moving Coil Instruments with Rectifier

Hauptbild - (K)PQg - Moving Coil Instruments with Rectifier
KPQg - Drehspulinstrumente mit Kreisskala und Gleichrichter - (K)PQg - Moving Coil Instruments with Rectifier
Austausch der Skala bei Schalttafeleinbaugeräten und Messgeräten zur Hutschienenmontage - (K)PQg - Moving Coil Instruments with Rectifier
240° Kreisskala - (K)PQg - Moving Coil Instruments with Rectifier
Skalenbeispiel 240° Kreisskala - (K)PQg - Moving Coil Instruments with Rectifier
Properties
  • AC current and voltage measurement

  • Exchange scale

  • Linear 90° scale (PQg)

  • Linear 240° scale (KPQg)

  • Good readability

  • High vibration and impact resistance

  • Terminal cover according to VGB 04 (option)

Description

The measuring instruments of the (K)PQg series have an integrated rectifier and are used to measure current and voltage in AC networks. While the PQg measuring instruments have a linear 90° scale, the KPQg circular scale instruments have a linear 240° scale.

Variants

PQg 45 45 mm for DIN rail mounting
PQg 48 48 x 48 mm for panel mounting
PQg 72 72 x 72 mm for panel mounting
PQg 96 96 x 96 mm for panel mounting
PQg 144 144 x 144 mm for panel mounting
KPQg 45 45 mm for DIN rail mounting
KPQg 48 48 x 48 mm for panel mounting
KPQg 72 72 x 72 mm for panel mounting
KPQg 96 96 x 96 mm for panel mounting
KPQg 144 144 x 144 mm for panel mounting

Application

The instruments with moving-coil movement and built-in rectifier are intended for panel mounting in power and low-current installations where measurements of alternating currents and voltages with a small intrinsic consumption of the measuring instrument are required. They measure the arithmetic mean value of the alternating current or voltage in a frequency range from 40 to 5000 Hz. The scale is displayed in r.m.s. values with sinusoidal form of the measured variable. Distortion of the sine curve causes measurement errors.

Mechanical Design

Germanium diodes with very low reverse current are used for rectification. The scales of the instrument are almost linear, except for voltmeters below 10V, where they are somewhat compressed in the initial part. For ammeters, a current transformer is built in for measurements with transducers .../1A and.../5A. The design of the housing makes it possible to change the scale more quickly, which means that different scale designs for measuring electrical and non-electrical quantities are possible with the measuring range remaining unchanged. If, for example, the primary value of an instrument connected via measuring transformers (ranges 1A, 5A, 100V) is changed, it is not necessary to install a new instrument, only the scale is replaced.

Technical Data

Technical Data

Accuracy class

1.5 (according to EN 60 051)

Housing

Polycarbonate self-extinguishing, according to UL 94 V-0

Protection class

Housing IP 52
Terminals IP 00 (IP 20 for size 45)
according to 60529: 1989

Mounting position

vertical ± 5°

Environmental Conditions

Climate class

2 according to VDE/VDI 3540

Temperature

Reference range +18 ... +28°C
Working range -25 ... +55°C
Storage -40 ... +70°C

Relative humidity

≤ 80 % (without condensation)

Measuring Ranges

Ammeter

Nominal value [μA]

100 µA up to 800 µA

Nominal value [mA]

1 mA up to 10 mA

Nennwert [A] - Current transformer

x A / 1 A     x A / 5 A1)

 

1)KPQg 48 only available with external current transformer 1 A/5 mA

Voltmeter

Nominal value [V]

2,5 V up to 600 V

Nominal value [V] - Voltage transformer

xV / 100 V2) xV / 110 V2)

 

2) For connection to transducers: transducer ratio and nominal range must be specified when ordering