Measurements of rms current, frequency, distortion factor and maximum values
Accuracy class 0.5 (EN 60688)
Input frequency ranges: 50/60 Hz, 400 Hz
RS232/RS485 interface (optional) with up to 115200 bit/s and USB 2.0 interface
MODBUS protocol
Auxiliary power supply via internal transformer or universal AC/DC module
Automatic range selection (max. 12 A)
Housing for DIN rail mounting
User-friendly MiQen software
Nominal frequency range
50/60, 400 Hz
Nominal values IN
1, 5, 10 A
Nominal current IN
5 A
Max. value
12,5 A sinusoidal
Max. permissible (thermal) limit value
15 A permanent20 × IN; 5 × 1s
Consumption
< I2 × 0.01Ohm per phase
Frequency measuring range(only for frequency measurements)
16 ... 400 Hz
The analogue output is fully programmable and can be set to one of the 6 ranges (4 current and 2 voltage ranges) without opening the unit.
Programmable DC current output:Output ranges 0 ... 100%
0 ... 1 mA
Range 1
0 ... 5 mA
Range 2
0 ... 10 mA
Range 3
0/4 ... 20 mA
Bereich 4
Other ranges
via MiQen software
Max. voltage level
10 V
Maximum load resistance
RB max =10 V / IoutN
Output ranges 0 ... 100%
0 ... 1 V
0 ... 10 V
Max. load current
20 mA
Min. load resistance
RBmin= UoutN / 10 mA